Celeb 200 DMX
Kelvin Color Temperature
Dimmer Level
Kelvin Color
Temperature
Dimmer
Level
5500K 100%
5000K 75%
4000K 50%
3200K 15%
2700K 0%
DMX Cables
DMX Cables
The Celeb 200 DMX xtures use ve-pin XLR male and
female connectors to receive DMX signals from the Dimmer
Board and jumper the xtures in a series. DMX pin-out
wiring follows the USITT DMX512 standard:
Pin 1: Shield
Pin 2: Data –
Pin 3: Date +
Pin 4: Spare –
Pin 5: Spare +
Note: Pin four and ve in the xture are connected internally
as Pin four to four and Pin ve to ve. Connecting Pin
four and ve as the pass-thru allows secondary data to be
passed through other equipment.
Do not use Microphone Cables and other general purpose, two-core cables designed
for audio or signaling use. They are not suitable for DMX512. Problems due to
incorrect cabling may not be immediately apparent. Microphone Cables may appear
to work ne, but systems built with such cables may fail or be prone to random errors.
Cable must comply with EIA-485 (RS485).
Note: The detailed DMX mapping for the Celeb 200 DMX xture can be downloaded
from the Operation Manual posted on www.kinoo.com.
IMPORTANT!
The dimmer board/light console should have its channel set to LINEAR light output
response. (LINEAR response is the default setting on most dimmer boards.)